Main camp product:Hall Open-loop current sensor  Hall closed-loop current senso  Hall Voltage Sensor  Magnet DC Current Sensor  
[

TBC-SY/SYW

]
sendmsg
ProductName: TBC-SY/SYW
ProductModel: PCB/Output Voltage
ProductManufacturer: Hall current sensor / CHINA HALL
ProductSimpleIntroduce
The TBC-SY/SYW series current sensor is a closed loop device based on the principle of the hall effect and null balance method.The output from the current sensor is the balancing current which is a perfect image of the primary current reduced by the number of secondary turns at any time.This current can be expressed as a voltage by passing it through a resister.It provides accurate electronic measurement of DC,AC or pulsed currents.


TBC-SY/SYW  detail

TBC-SY/SYW Series Hall Effect Current Sensor
DESCRIPTION
The TBC-SY/SYW series current sensor is a closed loop device based on the principle of the hall effect and null balance method.The output from the current sensor is the balancing current which is a perfect image of the primary current reduced by the number of secondary turns at any time.This current can be expressed as a voltage by passing it through a resister.It provides accurate electronic measurement of DC,AC or pulsed currents.

 

ELECTRICAL DATA

Type

TBC05SY/SYW

TBC10SY/SYW

TBC12.5SY/SYW

TBC15SY/SYW

 

 

TBC20SY/SYW

TBC25SY/SYW

TBC30SY/SYW

TBC50SY

 

 

Rated current

5

10

12.5

15

20

25

30

50

A

 

Measure range

15

30

37.5

45

60

75

90

150

A

 

Size of primary

ø 0.6

ø 0.8

ø 1.0

ø 1.0

ø 1.0

ø 1.4

ø 1.6

2×□1.6×1.5

mm

 

Turns

52500

33000

22500

23000

22500

12500

13000

13125

 

 

Internal measure resister(Rm)

400

±0.1%

400

±0.1%

400

±0.1%

400

±0.1%

250

±0.1%

400

±0.1%

400

±0.1%

250

±0.5%

Ω

 

Rated output

 

 

±4±0.5%

V

 

Supply voltage

 

 

±15±5%

V

 

Consumption current

Vo=OV

 

12

mA

 

Offset voltage

 

 

±20

mV

 

Offset drift

 

 

≤±0.5

mV/℃

 

Linearity

 

 

≤0.1

%FS

 

Response time

 

 

1

μS

 

Withstand voltage

50HZ,1min

 

5.0

KV

 

Operation temp

 

 

-40+85

 

Storage temp

 

 

-40+125

 

 

MUTING DIMENSIONS(FOR REFERENCE ONLY)




























 

 

 



DIRECTIONS FOR USE
1.When the current will be measured goes through a sensor,the voltage will be measured at the output end。(Note:The false wiring may result in the damage of the sensor).
2.Custom design in the nominal input current and the output voltage available.


Leave a message for product


Hall current sensor / CHINA HALL
Tel :025-84311092    Fax:025-84372728
Address:The westen zone of 5311plant , Biao Yin No.4#. Nanjing City, Jiangsu Provice, P.R.C.  
粤ICP备08118721号   SiteAdmin