Main camp product:Hall Open-loop current sensor  Hall closed-loop current senso  Hall Voltage Sensor  Magnet DC Current Sensor  
[

TBC-EH3

]
sendmsg
ProductName: TBC-EH3
ProductModel: Three high-precision measurements
ProductManufacturer: Hall current sensor / CHINA HALL
ProductSimpleIntroduce
TBC-EH3 series at the beginning of the current sensors, is among the sub-insulated, non-location of the error, can distinguish between real measurement of 1000:1, for the three-phase measurement precision DC, AC and pulse current.


TBC-EH3  detail

TBC-EH3 Three-phase series of high-precision Hall current sensor
TBC-EH3 series at the beginning of the current sensors, is among the sub-insulated, non-location of the error, can distinguish between real measurement of 1000:1, for the three-phase measurement precision DC, AC and pulse current.

ELECTRICAL DATA

Type

TBC25EH3

TBC50EH3

TBC100EH3

TBC200EH3

 

Rated current(Ip)

10-25

10-50

20-100

40-200

A

Measure range

75±18V200Ω

150±18V82Ω

300±18V33Ω

600±18V30Ω

A

Turns ratio

1:1000

1:1000

1:1000

1:2000

 

Measuring resistance with±12V

with±15V

@±25Amax 390(max)

@±50Amax 200(max)

@±100Amax 91(max)

@±200Amax 82(max)

Ω

@±75Amax 120(max)

@±150Amax 50(max)

@±300Amax 15(max)

@±600Amax 10 (max)

Ω

@±25Amax 510(max)

@±50Amax 270(max)

@±100Amax 120(max)

@±200Amax 100(max)

Ω

@±75Amax 150(max)

@±150Amax 68(max)

@±300Amax 25(max)

@±600Amax 20(max)

Ω

Rated output current
(Is)

1010A-

25(25A)±0.2%

1010A-

50(50A)±0.2%

2020A-

100(100A)±0.2%

2040A-

100(200A)±0.2%

mA

Supply voltage

 

 

 

±12±18

V

consumption(Is=0)

 

 

 

≤60

mA

Offset current

 

 

 

±0.2

mA

Offset drift

-40℃85℃

 

 

±0.5

mA

Response time

 

 

 

1

µs

Linearity

 

 

 

≤0.1

%FS

Galvanic isolation

50HZ,1min

 

 

3

KV

di/dt

 

 

 

200

A/μs

Band with(-3dB)

 

 

 

DC…100

KHz

Secondary resiste

30

25

20

25

Ω

Operating temperature

 

 

 

-40+85

Storage temperature

 

 

 

-40+125

MUTING DIMENSIONS(FOR REFERENCE ONLY)



DIRECTIONS FOR USE
1.Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
2.The primary conductor should be≤120℃;
3.The dynamic performance (di/dt and the response time)is the best when the primary hole is fully filled with the bus bar.
4.The primary turns should be at the top of the sensor for the best magnetic coupling.


Leave a message for product


Hall current sensor / CHINA HALL
Tel :025-84311092    Fax:025-84372728
Address:The westen zone of 5311plant , Biao Yin No.4#. Nanjing City, Jiangsu Provice, P.R.C.  
粤ICP备08118721号   SiteAdmin