Main camp product:Hall Open-loop current sensor  Hall closed-loop current senso  Hall Voltage Sensor  Magnet DC Current Sensor  
[

TBC-PX

]
sendmsg
ProductName: TBC-PX
ProductModel: Two-way /high-precision measurements
ProductManufacturer: Hall current sensor / CHINA HALL
ProductSimpleIntroduce
The TBC-PX series current sensor is a closed loop device based on the principle of the hall effect and null balance method.The output from the current sensor is the balancing current which is a perfect image of the primary current reduced by the number of secondary turns at any time.This current can be expressed as a voltage by passing it through a resister.It provides accurate electronic measurement of DC,AC or pulsed currents.


TBC-PX  detail

TBC-PX gimmal Series Hall Effect Current Sensor
The TBC-PX series current sensor is a closed loop device based on the principle of the hall effect and null balance method.The output from the current sensor is the balancing current which is a perfect image of the primary current reduced by the number of secondary turns at any time.This current can be expressed as a voltage by passing it through a resister.It provides accurate electronic measurement of DC,AC or pulsed currents.
 
ELECTRICAL DATA
 
Type
TBC03PX
TBC05PX
TBC10PX
TBC15PX
 
 
TBC20PX
TBC25PX
TBC30PX
TBC50PX
 
Rated current
3
5
10
15
20
25
30
50
    A
Measure range
9
15
30
45
60
75
90
150
    A
Turns
4:   7:2100
4:2000
2:2000
2:1875
1:2000
1:2500
1:1875
1:2500
 
Internal measure resister(Rm)
400±0.1%
400±0.1%
400±0.1%
250±0.1%
400±0.1%
400±0.1%
250±0.1%
200±0.1%
    Ω
Rated output
 
 
4±0.5%
    V
Supply voltage
 
 
±15±5%
    V
Offset current
 
 
±0.04
    V
Consumption current
 
 
 
≤±30±10X2(±16X2)
    mA
Linearity
 
 
≤0.1
%FS
Response time
 
 
<1
   µs
bandwidth(-3db)
 
 
0—150
   KHz
Out temperature drift
 
 
<±0.02
 %/℃
zerotemperature drift
 
 
±0.5
 mV/℃
Withstand voltage
50(60)HZ,1min
 
5.0
   KV
insulation strength
 
 
>1000
   MΩ
Operation temp
 
 
 
-40~+85
  
Storage temp
 
 
-40~+125
  
 
MUTING DIMENSIONS(FOR REFERENCE ONLY)

DIRECTIONS FOR USE
1.When the current will be measured goes through a sensor,the voltage will be measured at the output end。(Note:The false wiring may result in the damage of the sensor).
2.Custom design in the nominal input current and the output voltage available.


Leave a message for product


Hall current sensor / CHINA HALL
Tel :025-84311092    Fax:025-84372728
Address:The westen zone of 5311plant , Biao Yin No.4#. Nanjing City, Jiangsu Provice, P.R.C.  
粤ICP备08118721号   SiteAdmin